EVALUATION OF THE USE OF RADIATIVE COOLING TECHNOLOGY TO SUPPORT THE AIR CONDITIONING SYSTEM OF A DATA CENTRE

Autores/as

  • Jonathan Cofré-Toledo
  • Roger Vilà
  • Albert Castell
  • Ingrid Martorell

DOI:

https://doi.org/10.21134/ck1khq50

Palabras clave:

Data Centre, Air Conditioning, Radiative Cooling, Numerical Simulation, Energy Modelling

Resumen

Data centre space cooling systems consume a lot of energy and will increase over the years. Therefore, it is necessary to propose new refrigeration strategies. Radiative cooling (RC) production is a renewable alternative solution with a promising future. In this work, the energy modelling of the air conditioning system of a data centre coupled to a RC emitter is carried out to explore the benefits of this technology. The system consists of a water chiller connected to a cooling coil through which air is circulated for distribution in the data centre room. The simulations were carried out for a typical summer week in Barcelona. The RC production was carried out during the night, and this energy was used during the day and was implemented directly in the energy balance of the data centre room, considering emission surfaces of 80 and 60% of the total building roof, reducing the water chiller energy consumption by 13 and 10% respectively. In the transient behaviour of the temperature in the data centre room, when the RC was used to reduce the peak cooling load, a reduction of the temperatures was observed approaching to the design setpoint, therefore, the Information Technology (IT) equipment was not affected.

Referencias

Whitehead B, Andrews D, Shah A, Maidment G. Assessing the environmental impact of data centres part 1: Background, energy use and metrics. Building and Environment 2014;82:151–9. https://doi.org/10.1016/j.buildenv.2014.08.021.

Huang P, Copertaro B, Zhang X, Shen J, Löfgren I, Rönnelid M, et al. A review of data centers as prosumers in district energy systems: Renewable energy integration and waste heat reuse for district heating. Applied Energy 2020;258:114109. https://doi.org/10.1016/j.apenergy.2019.114109.

Brown R, Energy A to S, Incorporated ICF, Incorporated ERG, Agency USEP. Report to Congress on Server and Data Center Energy Efficiency: Public Law 109-431 2008.

Greenberg S, Mills E, Tschudi B, Rumsey P, Myatt B. Best practices for data centers: Lessons learned from benchmarking 22 data centers. Proceedings of the ACEEE Summer Study on Energy Efficiency in Buildings in Asilomar, CA ACEEE, August 2006;3:76–87.

Koronen C, Åhman M, Nilsson LJ. Data centres in future European energy systems—energy efficiency, integration and policy. Energy Efficiency 2020;13:129–44. https://doi.org/10.1007/s12053-019-09833-8.

Wang L, Chen X, Chen L, Li Z. Radiative Cooling Technology for Data Center Cooling Systems. 15th International Conference on Applied Energy (ICAE2023)) 2024;46.

EnergyPlus n.d. https://energyplus.net/ (accessed April 24, 2024).

Data Center Temperature Rise After Primary Power Loss Calculator n.d. https://www.se.com/ww/en/work/solutions/system/s1/data-center-and-network-systems/trade-off-tools/data-center-temperature-rise-after-primary-power-loss-calculator/ (accessed April 24, 2024).

David MP, Schmidt RR. Impact of ASHRAE environmental classes on data centers. Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm), 2014, p. 1092–9. https://doi.org/10.1109/ITHERM.2014.6892403.

Ҫengel Y, Ghajar A. Transferencia de calor y masa, fundamentos y aplicaciones 2011.

PDRC | ChillSkyn Solutions. ChillSkyn - PDRC n.d. https://www.chillskyn.com (accessed April 25, 2024).

Descargas

Publicado

2024-10-22